en:wiki:funktionen:td-functions:frequency_dependent_window
Differences
This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
en:wiki:funktionen:td-functions:frequency_dependent_window [23/06/2016 11:01] – created uli | en:wiki:funktionen:td-functions:frequency_dependent_window [25/09/2016 16:18] (current) – hamish | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | + | ====== Frequency | |
- | + | ||
- | | + | |
- | //(remove this paragraph once the translation is finished)// | + | |
- | ====== Frequency | + | |
{{: | {{: | ||
\\ | \\ | ||
- | **Beschreibung:** \\ | + | **Description:** \\ |
- | Die FDW ist ein mächtiges Werkzeug, welches einen definierten Teil Informationen aus einer [[: | + | The FDW is a powerful tool for reducing the effect of room reverberations on pulse response. The FDW examines the [[:en: |
\\ | \\ | ||
- | **Optionen:** | + | **Options:** |
- | | + | |
- | - Gibt die Länge des Zeitfensters nach dem Maximalwert der Pulsantwort | + | - Specifies the time in cycles to be accepted after the pulse peak. The first number applies at 20Hz and the second at 20kHz. The window adjusts smoothly between those frequencies. |
- | - ??? | + | - Sorry - There is no 3. |
- | - Eingabe der verwendeten Glättung der Kurve | + | - The smoothing in frequency response in the frequency domain to be applied after the FDW analysis |
- | - ??? | + | - Set automatically by Acourate to the position of the highest sample. If that is not the true center of the pulse, it can be edited manually. |
- | - ??? | + | - Examine just the left side of the peak (before the peak), both sides of the peak, or the right side of the peak (after the peak). |
- | \\ **Verwendung:** \\ Eine [[: | + | \\ **Use:** \\ A pulse response also contains complete information about the environment |
- | \\ | + | |
- | Die FDW ist auch Teil der Filtererstellung in [[: | + | |
- | \\ **Beispiel: | + | The FDW is also part of the filter creation in Room Macro 1, where the values are set to 15/15. In practice, this makes meaningful improvements and is usually a good compromise between hiding the room information and including enough speaker information to provide meaningful results. These values can be, for example, adjusted by ear. Since each system of speaker / room has different properties, values that might theoretically be considered " |
en/wiki/funktionen/td-functions/frequency_dependent_window.txt · Last modified: 25/09/2016 16:18 by hamish